In the preceding sections, using the circuit conduction mode as an example, we examined the distinct behavior of inductor current across continuous and discontinuous boundaries: CCM sustains steady output under heavy-load conditions via continuous current conduction; DCM achieves a trade-off between efficiency and cost in light-load scenarios through current returning to zero periodically; and Forced CCM (FCCM) employs a 'rigorous' approach by forcing the current across the zero axis, trading lower efficiency for constant switching frequency and enhanced transient response predictability. Together, these three modes form a complete 'current continuity spectrum,' addressing a single fundamental question: how is the energy stored in the inductor transformed by the end of each switching cycle?

Similarly, beyond the dimension of current continuity, power converters are governed by another control axis that equally profoundly impacts the inductor—the modulation strategy. Rather than asking 'whether the current returns to zero,' it addresses another fundamental question: at what rhythm and magnitude do the power switches operate? The former is jointly determined by the inductance value and the load condition, while the latter is actively governed by the controller IC, leaving the inductor to act as a passive 'executor.'

Figure 1. Pulse-Width Modulation (PWM)

Figure 2. Pulse-Frequency Modulation (PFM)

Figure 3. Pulse-Skipping Modulation (PSM)

Figure 4. Circuit Modulation Modes
1.Fixed-Frequency vs. Variable-Frequency Control: Circuit Control Logic
By utilizing high-frequency switching, DC-DC switching regulators perform efficient power conversion and voltage regulation governed by a closed-loop output feedback system. Whenever output voltage deviations occur, the negative feedback loop dynamically modulates the switching elements to maintain a tightly regulated output. Among the various modulation strategies, Pulse-Width Modulation (PWM), Pulse-Frequency Modulation (PFM), and Pulse-Skipping Modulation (PSM) constitute the three most representative control paradigms. Their fundamental distinction does not stem from a physical boundary such as whether the inductor current returns to zero, which differentiates CCM, DCM, and FCCM. Rather, it originates from the control logic's temporal scheduling strategy for switching operations: whether employing a fixed rhythm, an elastic rhythm, or selective skipping.
There is no absolute superiority or inferiority among the three modulation strategies; rather, their deployment depends entirely on trade-offs matched to system requirements. Understanding the differential stress they impose on the inductor is the first step toward proper component selection—in the subsequent chapters, we will delve into the respective current waveform characteristics, core loss components, and key parameter weight variations of PWM, PFM, and PSM, providing engineers with a clear roadmap through complex selection decisions.
● In Pulse-Width Modulation (PWM) mode, the switching frequency remains constant, and output voltage regulation is achieved by varying the pulse width—namely, the duty cycle. The duty cycle is defined as the ratio of the power switch turn-on time Ton to the switching period T, where Ton (turn-on time) plus Toff (turn-off time) equals T (switching period),
expressed as duty cycle D = Ton / T.
Under PWM control, the power switches operate continuously, maintaining an identical switching frequency under both heavy-load and light-load conditions. Consequently, switching losses become the dominant loss mechanism at light loads, resulting in relatively lower conversion efficiency. With a constant switching frequency, PWM control produces a fixed-frequency, low-amplitude output voltage ripple. Additionally, its concentrated EMI frequency spectrum simplifies noise mitigation via magnetic shielding and EMI filter design.
● In Pulse-Frequency Modulation (PFM) mode, output voltage regulation is achieved by varying the switching pulse frequency while keeping the pulse width constant. Typically, PFM is implemented in two primary topologies: constant on-time (COT) control and constant off-time control.
Under PFM control, switching losses are significantly reduced at light loads by lowering the switching frequency, thereby delivering high conversion efficiency. However, because the switching frequency varies with the operating state, the output ripple frequency and amplitude change accordingly. The ripple amplitude fluctuates widely across different load conditions, making it challenging to fully filter out using fixed-parameter filter circuits. Furthermore, due to the variable switching frequency, the electromagnetic interference (EMI) spectrum is widely distributed, potentially generating noise across a broad frequency range and complicating EMI suppression.
● In Pulse-Skipping Modulation (PSM) mode, the switching clock frequency remains fixed, and output voltage regulation is achieved by selectively skipping switching cycles. Within each fixed-length switching period, the control loop determines whether to initiate a switching event based on the output voltage droop: when the output voltage falls below a preset threshold, the power switch turns on normally to deliver energy to the load; conversely, when the output voltage exceeds the threshold, the cycle is "skipped," keeping the power switch off for the entire period while the inductor current decays to and remains at zero until the next active pulse arrives.
Under PSM control, the switching clock frequency remains macroscopically constant, whereas the distribution of active pulses along the time axis exhibits a pattern of alternating density and sparsity. Under light-load conditions, a large number of switching cycles are skipped, substantially reducing the effective switching count. Consequently, both switching losses and gate-drive losses drop significantly, yielding conversion efficiency intermediate between PWM and PFM.
2. Power Inductor Selection: Impact Parameters of FCCM
(1) Saturation Current
Peak current margin is a fundamental criterion in power inductor selection, with the peak current experienced by the inductor exhibiting significant differences across various modulation strategies:
Under PWM control, the peak inductor current is determined by the duty cycle, input and output voltages, and the inductance value. During steady-state operation, the cycle-by-cycle peak current remains constant with smooth amplitude variations. Consequently, component selection only requires reserving an appropriate current margin (approximately 20%) based on the peak current under maximum load conditions, thereby ensuring that magnetic saturation is avoided across the entire load range.
Under PFM control, because the switching frequency is drastically reduced at light loads, each active pulse must transfer significantly more energy than in PWM mode to maintain the output voltage. Consequently, the peak current per pulse in PFM is often substantially higher than that of PWM under identical load conditions. Therefore, even though the actual load may be light, inductor selection requires a more generous current margin (30% or higher) compared to PWM operation to prevent magnetic saturation.
Under PSM control, peak current challenges stem primarily from transient surges. When operating at full load, PSM behavior aligns with that of PWM. However, the critical challenge arises when resuming operation from skipped idle cycles: the magnetic core, starting from an initial 'zero-magnetization' state, must rapidly build up current from zero to full peak within the very first full-amplitude pulse. If the magnetic core material exhibits insufficient response speed, or if the current margin is reserved solely for steady-state operating conditions, this 'recovery pulse' may exceed preset thresholds. Therefore, it is recommended to reserve a current margin intermediate between PWM and PFM (approximately 20% to 30%) during inductor selection.
(2) High-Frequency Core Losses and Material Characteristics
Core losses are defined as the thermal power dissipated within the magnetic core under alternating flux conditions, driven by hysteresis and eddy currents. As the switching frequency increases, core losses escalate significantly. Among the three modulation modes, core loss considerations carry the highest weight in PWM design.
Under PWM control, with a constant switching frequency, the magnetic core undergoes a complete magnetization-demagnetization cycle every period, resulting in a fixed magnetic flux swing. This means that regardless of the load level, core losses persist continuously at full-load levels. Therefore, in PWM applications—particularly under high-frequency operation—core loss performance serves as a more critical selection criterion than DCR (DC Resistance). Priority should be given to magnetic powder core materials featuring high-frequency, low-loss characteristics.
Conversely, core loss considerations carry a lower relative priority in PFM and PSM modes. In PFM mode, the switching frequency decreases sharply under light loads, cutting the frequency of flux reversals and proportionally reducing core losses. Similarly, PSM completely suspends switching during skip intervals, granting the magnetic core sufficient dormant periods. As a result, core dissipation does not dominate thermal rise at light loads in either mode.
(3) Inductance Stability
Inductance stability refers to the capability of an inductor to maintain its nominal inductance value under actual operating conditions, such as DC bias, ambient temperature variations, and aging. Typically, under PWM and PFM operation, moderate inductance variations can be accommodated by loop compensation, provided the inductor does not enter saturation across the entire load range, thereby ensuring fundamental system stability.
By contrast, since PSM relies on output voltage sag to trigger active operating pulses, inductance stability directly governs the voltage droop slew rate during skip cycles. Consequently, inductors featuring flat DC bias characteristics—exhibiting minimal inductance variation across a wide current range—should be selected.
3.Codaca Inductor Solutions for Power Converters
Through independent R&D and technological innovation, Codaca provides differentiated inductor solutions tailored for DC-DC converters across diverse modulation strategies. Whether addressing continuous core and copper losses under high-frequency PWM, saturation margin constraints from high pulse peak currents during light-load PFM, or the challenges of transient surges and bias drift on inductance stability during PSM skip-cycle recovery, each of these operating scenarios imposes rigorous performance demands on power inductors as key passive components. Featuring superior DC bias characteristics and high saturation current ratings, Codaca’s proprietary magnetic powder core high-current inductors effectively withstand peak current surges across all modulation modes, preventing thermal runaway and output voltage sag caused by core saturation. Furthermore, by combining low-loss magnetic core materials with flat-wire winding technology, these inductors simultaneously address both core loss and AC resistance, minimizing additional losses induced by high-frequency switching.

Whether designing for PWM with its focus on high-frequency low loss and deterministic response, PFM prioritizing light-load energy efficiency, or PSM balancing efficiency against acoustic and EMI noise, Codaca provides comprehensive inductor solutions covering all operating scenarios—empowering engineers to achieve an optimal balance among performance, efficiency, and reliability.